Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 32
Filter
1.
Braz. dent. j ; 34(4): 62-71, July-Aug. 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1520328

ABSTRACT

Abstract This study aimed to evaluate the effect of antioxidant solutions on fracture strength and bonding performance in non-vital and bleached (38% hydrogen peroxide) teeth. One hundred and eighty dentin specimens were obtained, 60 for each test: fracture strength, hybrid layer thickness, and bond strength. The groups (n=10) were randomly composed according to post-bleaching protocol: REST - restoration, without bleaching; BL - bleaching + restoration; SA - bleaching, 10% sodium ascorbate solution, and restoration; AT - bleaching, 10% α-tocopherol solution, and restoration; CRAN - bleaching, 5% cranberry solution, and restoration; CAP - bleaching, 0.0025% capsaicin solution, and restoration. Data were analyzed with ANOVA, Kruskal-Wallis, Dunn, and Qui-Square tests (α=0.05). The highest fracture strength values were observed in REST (1508.96 ±148.15 N), without significant difference for the bleached groups (p>0.05), regardless of the antioxidant use. The hybrid layer thickness in the group that was not subjected to bleaching (REST) was significantly higher than in any other group. The bond strength in the bleached and antioxidants-treated groups (SA, AT, CRAN, CAP) has no differences with the bleached group without antioxidants (BL). Adhesive failures were predominant in the groups that did not receive the antioxidant application. In conclusion, the evaluated antioxidants did not show an effect on the fracture strength, hybrid layer thickness, or bond strength of dentin bleached after endodontic treatment. The application of 10% sodium ascorbate, 10% alpha-tocopherol, 5% cranberry, or 0.0025% capsaicin solutions is not an effective step and should not be considered for the restorative protocols after non-vital bleaching.


Resumo Este estudo teve como objetivo avaliar o efeito de soluções antioxidantes na resistência à fratura e resistência de união em dentes tratados endodonticamente e clareados (38% de peróxido de hidrogênio). Cento e oitenta espécimes de dentina foram obtidos, 60 para cada teste: resistência à fratura, espessura da camada híbrida e resistência de união. Os grupos (n=10) foram compostos aleatoriamente de acordo com o protocolo pós-clareamento: REST - restauração, sem clareamento; BL - clareamento + restauração; SA - clareamento, solução de ascorbato de sódio a 10% e restauração; AT - clareamento, solução de α-tocoferol a 10% e restauração; CRAN - clareamento, solução de cranberry a 5% e restauração; CAP - clareamento, solução de capsaicina 0,0025% e restauração. Os dados foram analisados ​​com os testes ANOVA, Kruskal-Wallis, Dunn e Qui-Quadrado (α=0,05). Os maiores valores de resistência à fratura foram observados em REST (1508,96 ±148,15 N), sem diferença significativa para os grupos clareados (p>0,05), independente do uso de antioxidantes. A espessura da camada híbrida no grupo que não foi submetido ao clareamento (REST) foi significativamente maior do que em qualquer outro grupo. A resistência de união nos grupos clareado e tratado com antioxidantes (SA, AT, CRAN, CAP) não apresentou diferenças com o grupo branqueado sem antioxidantes (BL). As falhas adesivas foram predominantes nos grupos que não receberam a aplicação do antioxidante. Em conclusão, os antioxidantes avaliados não mostraram efeito sobre a resistência à fratura, espessura da camada híbrida ou resistência de união à dentina clareada após tratamento endodôntico. A aplicação de soluções de ascorbato de sódio 10%, alfa-tocoferol 10%, cranberry 5% ou capsaicina 0,0025% não é uma etapa eficaz e não deve ser considerada para os protocolos restauradores após clareamento não vital.

2.
Braz. dent. j ; 34(4): 115-126, July-Aug. 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1520337

ABSTRACT

Abstract This study was aimed at analyzing the surface properties of a universal resin composite and evaluating the effect of preheating on its physicochemical properties. Two commercial resin composites were used under two conditions: Filtek Universal Restorative (UR); UR preheated (URH); Filtek Supreme (FS) and FS preheated (FSH). The film thickness (FT) test (n = 10) was done using two glass slabs under compression. Flexural strength (FLS) and modulus (FLM) were evaluated using a three-point flexion test (n = 10). Polymerization shrinkage stress (PSS) was evaluated in a universal testing machine (n = 5). Gap width (GW) between composite and mold was measured in internally polished metallic molds (n = 10). The degree of conversion (DC) was evaluated by Fourier Transform Infrared spectroscopy (n = 3). The morphology of the filler particles was checked by scanning electron microscope (SEM) and EDX analysis. Surface gloss (SG) and surface roughness (SR) were evaluated before and after mechanical brushing (n = 10). The outcomes were submitted to 2-way ANOVA and Tukey's test (α = 0.05). Lower mean values of FT were observed for the preheated groups when compared to the non-preheated groups. URH and FSH showed higher mean values of FLS and FLM when compared with UR and FS. No differences were observed between groups in the PSS test. The GW was higher for the UR and FS groups when compared with URH and FSH. The DC was higher for preheated resin composites when compared to the non-preheated groups. The SR of the UR composite was higher than the FS after mechanical brushing, while the SG was higher for the FS groups. In conclusion, the universal resin composite tested generally presented similar physicochemical properties compared with the nanofilled resin composite and either similar or slightly inferior surface properties. The preheating improved or maintained all properties evaluated.


Resumo Neste estudo avaliou-se propriedades físico-químicas e de superfície de um compósito universal pré-aquecido e comparado a um compósito convencional. Foram utilizados dois compósitos comerciais: Filtek Universal Restorative (UR); UR pré-aquecido (URH); Filtek Supreme (FS) e FS pré-aquecido (FSH). O teste de espessura de película (EP) (n = 10) foi feito usando duas placas de vidro sob compressão. A resistência à flexão (RF) e o módulo flexural (MF) foram avaliados por meio do teste de flexão de três pontos (n = 10). A tensão de contração de polimerização (TCP) foi avaliada em uma máquina de teste universal (n = 8). A largura da fenda (LF) entre o compósito e o molde foi medida em moldes metálicos polidos internamente (n = 10). O grau de conversão (GC) foi avaliado por espectroscopia de infravermelho com transformada de Fourier (n = 3). A morfologia das partículas de carga foi observada em microscopia eletrônica de varredura (MEV) e sua composição em EDX. Brilho superficial (BS) e rugosidade superficial (RS) foram avaliados antes e após escovação mecânica (n=10). Os resultados foram submetidos à ANOVA 2-fatores e as médias comparadas pelo teste de Tukey (α = 0,05). Menores valores médios de EP foram observados para os grupos pré-aquecidos quando comparados aos grupos não pré-aquecidos. URH e FSH apresentaram maiores valores médios de RF e MF quando comparados com UR e FS. Não foram observadas diferenças entre os grupos no teste TCP. A LF foi maior para os grupos UR e FS quando comparados com URH e FSH. O GC foi maior para os compósitos pré-aquecidos quando comparados aos não pré-aquecidos. A RS do compósito UR foi maior que o FS após a escovação mecânica, enquanto o BS foi maior para os grupos FS. Em conclusão, o compósito universal testado geralmente apresentou propriedades físico-químicas semelhantes em comparação ao compósito nanoparticulado e propriedades de superfície semelhantes ou ligeiramente inferiores. O pré-aquecimento melhorou ou manteve todas as propriedades avaliadas.

3.
Article in English | LILACS-Express | LILACS | ID: biblio-1405312

ABSTRACT

ABSTRACT: The objective of this in vitro study was to evaluate the effects of finishing protocols and oral hygiene procedures on the surface and mechanical properties of CAD/CAM ceramics. Specimens (n = 96, (15x10x2mm) of the leucite glass-ceramic (LGC) and feldspathic ceramic (FP) received mechanical polishing or glazing. Surface roughness (Ra) and microhardness (VHN) were obtained with a profilometer and a hardness tester, respectively, before and after each oral hygiene procedure (TB: toothbrushing; PB: prophylaxis with paste and rubber cup; and BJ: prophylaxis with bicarbonate jet). ANOVA, paired t and Tukey's tests were applied (a=0.05). For both materials, only BJ affected Ra's values when mechanical polishing was performed. Moreover, no significant variations in VHN were observed only for LGC glazed with TB. Significant Ra and VHN changes in both materials were observed with BJ. Besides, BJ exhibited similar effects to TB on VHN, regardless of the material and finishing protocol used. Changes in mechanical and surface properties varied with the finishing protocol and the oral hygiene method. In general, prophylaxis with bicarbonate jet was the most harmful method for both materials and the type of finishing protocol did not have a protective effect against changes produced by oral hygiene methods.


RESUMEN: El objetivo de este estudio in vitro fue evaluar los efectos de los protocolos de acabado y los procedimientos de higiene oral sobre la superficie y las propiedades mecánicas de las cerámicas CAD/CAM. Los especímenes (n = 96, (15x10x2mm) de vitrocerámica de leucita (LGC) y cerámica feldespática (FP) recibieron pulido mecánico o glaseado. La rugosidad de la superficie (Ra) y la microdureza (VHN) se obtuvieron con un perfilómetro y un probador de dureza, respectivamente, antes y después de cada procedimiento de higiene oral (TB: cepillado dental; PB: profilaxis con pasta y vaso de hule; y BJ: profilaxis con chorro de bicarbonato). Se aplicaron ANOVA, t pareada y prueba de Tukey (a=0.05). Para ambos materiales, solo BJ afectó los valores de Ra cuando se realizó el pulido mecánico. Además, no se observaron variaciones significativas en VHN solo para LGC vidriado con TB. Se observaron cambios significativos de Ra y VHN en ambos materiales con BJ. Además, BJ exhibió efectos similares a TB en VHN, independientemente del material y protocolo de acabado utilizado Los cambios en las propiedades mecánicas y superficiales variaron con el protocolo de acabado y el método de higiene oral. En general, la profilaxis con chorro de bicarbonato fue el método más perjudicial, tanto los materiales como el tipo de protocolo de acabado no tuvieron un efecto protector frente a los cambios producidos por los métodos de higiene oral.

4.
Braz. dent. j ; 33(1): 68-76, jan.-fev. 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1364479

ABSTRACT

Abstract This in vitro study evaluated the anti-erosive effect of an experimental varnish containing 5% stannous chloride (SnCl₂) associated with different concentrations of NaF (NaF-free, 2.5% NaF, or 5.2% NaF) on bovine enamel and root dentin. One hundred samples were pre-eroded (0.3% citric acid, pH 2.6, 10 min) and randomized into five groups (n=10 for each substrate): Negative control - milli-Q water; NaF-free - Experimental varnish SnCl₂-free and NaF-free; 2.5 NaF - Experimental varnish 5% SnCl₂ associated with 2.5% NaF; 5.2 NaF: Experimental varnish 5% SnCl₂ associated with 5.2% NaF and positive control - Commercial varnish containing 5% NaF (Duraphat). After the varnishes were applied, the erosive and abrasive challenges were carried out for five days. Loss of tooth structure (TSL) was determined by optical profilometry, and the loss of calcium (ΔCa2+) using atomic absorption spectroscopy. Dentin analysis was also performed by SEM. A one-way ANOVA/Bonferroni test was performed to analyze the data (α=0.05). The experimental 2.5 NaF and 5.2 NaF groups showed greater effectiveness in preventing TSL when compared to the other groups (p <0.05), regardless of the substrate. In addition, these groups showed lower loss in Ca2+ content when compared to the other groups (p <0.05), for enamel and dentin. Dentin showed greater TSL and ΔCa2+ loss when compared to enamel in all treatments (p <0.05). The 5.2% and 2.5% NaF-containing experimental varnishes showed promising results in both, the prevention of TSL and the loss of Ca2+, regardless of the substrate studied.


Resumo Este estudo in vitro avaliou o efeito anti-erosivo de um verniz experimental contendo 5% de cloreto estanoso (SnCl₂) associado a diferentes concentrações de NaF (sem NaF, 2,5% NaF ou 5,2% NaF) sobre esmalte e dentina radicular bovinos. Cem amostras foram pré-erodidas (ácido cítrico 0,3%, pH 2,6, 10 min) e randomizadas em cinco grupos (n=10 para cada substrato): Controle negativo - água milli-Q; Sem NaF - Verniz experimental sem SnCl2 e sem NaF; 2,5 NaF - Verniz experimental 5% SnCl2 associado a 2,5% NaF; 5,2 NaF: Verniz experimental 5% SnCl2 associado a 5,2% NaF e controle positivo - Verniz comercial contendo 5% NaF (Duraphat). Após a aplicação dos vernizes, os desafios erosivos e abrasivos foram realizados por cinco dias. A perda de estrutura dentária (PED) foi determinada por perfilometria óptica e a perda de cálcio (ΔCa2+) por espectroscopia de absorção atômica. A análise da dentina também foi realizada por MEV. Um teste ANOVA/Bonferroni de uma via foi realizado para analisar os dados (α=0,05). Os grupos experimentais 2,5 NaF e 5,2 NaF apresentaram maior eficácia na prevenção de PED quando comparados aos demais grupos (p<0,05), independentemente do substrato. Além disso, esses grupos apresentaram menor perda no teor de Ca2+ quando comparados aos demais grupos (p<0,05), para esmalte e dentina. A dentina apresentou maior PED e de ΔCa2+ quando comparada ao esmalte em todos os tratamentos (p<0,05). Os vernizes experimentais contendo NaF 5,2% e 2,5% apresentaram resultados promissores tanto na prevenção de PED quanto na perda de Ca2+, independente do substrato estudado.

5.
J. health sci. (Londrina) ; 23(1): https://revista.pgsskroton.com/index.php/JHealthSci/article/view/7935, 20210330.
Article in English | LILACS-Express | LILACS | ID: biblio-1179423

ABSTRACT

The teeth weakening due to the preparation of class II mesio-occluso-distal cavities is a challenge for the clinician. The objective of this study was to evaluate the molars fracture resistance with class II mesio-occluso distal cavities restored with different restorative techniques and materials. Forty extracted molars were divided into 5 groups: Group 1 ­ intact healthy teeth (positive control); Group 2 ­ unrestored teeth with mesio-occluso distal class II cavities (negative control); Groups 3 to 5 ­ restored teeth with standardized dimensions. In groups 3 to 5, the cavities were restored with flow resin only, flow resin coated with a nano-hybrid resin, and nano-hybrid resin only, respectively. All specimens were tested for resistance to fracture using an axial compressive load, a metallic sphere measuring 8 mm in diameter on a universal testing machine EMIC DL-2000. A 10 kN load cell operated at a speed of 5 mm/min until the tooth fracture. Data were subjected to analysis of variance and Tukey's tests (α = 0.05). Group 3 showed higher fracture strength (2243.1 ± 473.7N) when compared to groups 2, 4 and 5. This difference was statistically significant (p<0.05). The fracture strength of teeth restored with flow mesio occluso-distal restorations was similar to that of intact natural teeth. (AU)


O enfraquecimento dos dentes devido às preparações de cavidades mesio-ocluso-distal é um desafio para o clínico. O objetivo deste estudo foi avaliar a resistência à fratura de molares com cavidades mesio-ocluso-distais classe II restauradas com diferentes técnicas e materiais restauradores. Quarenta molares extraídos foram divididos em 5 grupos: Grupo 1 ­ dentes saudáveis intactos (controle positivo); Grupo 2 ­ dentes não restaurados com cavidades mesio-occluso-distais classe II (controle negativo); Grupos 3 a 5 ­ dentes restaurados com dimensões padronizadas. Nos grupos 3 a 5, as cavidades foram restauradas apenas com resina flow, resina flow recoberta com uma resina nanohíbrida e somente resina nano-híbrida, respectivamente. Todas as amostras foram testadas quanto à resistência à fratura usando uma carga compressiva axial, usando uma esfera metálica medindo 8 mm de diâmetro em uma máquina de teste universal EMIC DL-2000. Uma célula de carga de 10 kN operava a uma velocidade de 5 mm/min até a fratura do dente. Os dados foram submetidos à análise de variância e testes de Tukey (α = 0,05). O grupo 3 apresentou maior resistência à fratura (2243,1 ± 473,7N) quando comparado aos grupos 2, 4 e 5. Essa diferença foi estatisticamente significante (p <0,05). A resistência à fratura dos dentes restaurados com resina flow foi semelhante à dos dentes naturais intactos. (AU)

6.
Int. j. odontostomatol. (Print) ; 14(1): 60-66, mar. 2020. tab, graf
Article in English | LILACS | ID: biblio-1056502

ABSTRACT

ABSTRACT: The objective of the study was to evaluate marginal adaptation of Class II mesial-occlusal-distal (MOD) restorations before and after thermo-mechanical loading and volumetric shrinkage of the bulk-fill vs conventional composite resin. For marginal adaptation assessment, 24 Class II MOD cavities with cervical margins extending 1.0 mm below (distal) and 1.0 mm beyond (mesial) the cement-enamel junction were prepared in extracted human molars. The teeth were filled as follows: Group A - bulk-fill with SureFil SDR flow (first increment, 4 mm; second increment, 2 mm); Group B - bulk-fill with SureFil SDR flow as a base (first increment, 4 mm) and covered with the conventional nanohybrid composite Esthet-X HD (second increment, 2 mm); and Group C - incrementally filled with Esthet-X HD. Marginal adaptation was evaluated by scanning electron microscopy before and after thermomechanical loading (240,000 loading cycles and simultaneous 600 thermal cycles). To evaluate volumetric polymerization shrinkage, a semi-spherical mold was filled with the tested composites and placed in an AccuVol device after light curing. Both before and after loading, marginal adaptation in cervical dentin was superior (p < 0.05) for Groups A and B compared with Group C. In cervical enamel, Group B showed better marginal adaptation than Group C, and Group A presented intermediary results, between Groups B and C. Furthermore, bulk-fill flow resulted in greater shrinkage than Esthet-X HD. A significant improvement of marginal adaptation was observed when bulkfill flow was used instead of conventional composite resin both before and after thermomechanical loading. However, the bulk-fill flow presented higher volumetric polymerization shrinkage than the conventional composite.


RESUMEN: El objetivo de este trabajo consistió en evaluar la adaptación marginal de las restauraciones mesiales-oclusales-distales (MOD) de Clase II antes y después de la carga termo-mecánica y la contracción volumétrica de la carga compuesta de resina "bulk-fill" en comparación con resina convencional. Para la evaluación de adaptación, se prepararon 24 cavidades MOD de Clase II en molares humanos extraídos, los que se restauraron de la siguiente manera: Grupo A: restaurado con resina fluida Bulk-Fill SureFilSDR (primer incremento, 4 mm; segundo incremento, 2 mm); Grupo B: restaurado con resina fluida Bulk-Fill SureFil SDR (primer incremento, 4 mm) y cubierto con resina compuesta nanohíbrida Esthet-X HD (segundo incremento, 2 mm); y Grupo C - rellenado incrementalmente con Esthet-X HD. La adaptación marginal se evaluó mediante microscopía electrónica de barrido antes y después de la carga termomecánica (240.000 ciclos de carga y 600 ciclos térmicos simultáneos). Para evaluar la contracción volumétrica de la polimerización, se llenó un molde semiesférico con los compuestos probados y se colocó en un dispositivo AccuVol después del fotopolimerización. Tanto antes como después de la carga, la adaptación marginal en la dentina cervical fue superior (p <0,05) para los grupos A y B en comparación con el grupo C. En el esmalte cervical, el grupo B mostró una mejor adaptación marginal que el grupo C, y el grupo A presentó resultados intermedios, entre Grupos B y C. Se observó una mejora significativa de la adaptación marginal al utilizar la resina fluida Bulk-Fill en lugar de resina compuesta convencional tanto antes como después de la carga termomecánica. Sin embargo, la resina fluida 'Bulk-Fill' presentó una mayor contracción volumétrica de polimerización que el compuesto convencional.


Subject(s)
Humans , Dental Marginal Adaptation , Composite Resins , Dental Cavity Preparation/instrumentation , Dental Restoration, Permanent/methods , Malocclusion, Angle Class II , Stress, Mechanical , Ethics Committees , Dental Restoration Wear , Dental Cavity Preparation/standards , Polymerization
7.
Braz. oral res. (Online) ; 33: e026, 2019. tab, graf
Article in English | LILACS | ID: biblio-1001604

ABSTRACT

Abstract: The aim of this study is to evaluate the machinability of four CAD/CAM materials (n = 13) assessed by brittleness index, Vickers hardness, and fracture toughness and interaction among such mechanical properties. The materials selected in this in vitro study are Feldspathic ceramic [FC], Lithium-disilicate glass ceramic [LD], leucite-reinforced glass ceramic [LR], and nanofilled resin material [RN]. Slices were made from the blocks following original dimensions 14 × 12 × 3 mm (L × W × H), using a precision slow-speed saw device and then surfaces were regularized through a polishing device. Brittleness index and fracture toughness were calculated by the use of specific equations for each one of the properties. The Vickers hardness was calculated automated software in the microhardness device. One-way Anova and Pearson's correlation were applied to data evaluation. LD obtained the highest values for brittleness index and was not significantly different from FC. LR presented statistically significant difference compared with RN, which had the lowest mean. Vickers hardness showed LD with the highest average, and no statistical difference was found between FC and LR. RN presented the lowest average. Fracture toughness showed FC and LR not statistically different from each other, likewise LD and RN. The brittleness index, considered also as the machinability of a material, showed within this study as positively dependent on Vickers hardness, which leads to conclusion that hardness of ceramics is related to its milling capacity. In addition, fracture toughness of pre-sintered ceramics is compared to polymer-based materials.


Subject(s)
Polymers/chemistry , Ceramics/chemistry , Computer-Aided Design , Resin Cements/chemistry , Dental Porcelain/chemistry , Aluminum Silicates/chemistry , Reference Values , Surface Properties , Materials Testing , Reproducibility of Results , Analysis of Variance , Statistics, Nonparametric , Hardness Tests
8.
Rev. odontol. UNESP (Online) ; 48: e20190007, 2019. tab
Article in Portuguese | LILACS, BBO | ID: biblio-991492

ABSTRACT

Resumo Introdução Os adesivos autocondicionantes apresentam técnica adesiva simplificada e diminuição na sensibilidade pós-operatória. Quando aplicados sobre a dentina, atuam sobre a smear layer, cuja efetiva remoção ainda constitui um desafio. Uma substância utilizada como pré-tratamento dentinário na ajuda da remoção da smear layer é o etilenodiamino tetracético dissódico (EDTA). Objetivo Avaliar os efeitos do EDTA em associação com sistemas adesivos autocondicionantes na resistência de união ao microcisalhamento. Material e método Foram seccionadas as superfícies oclusais de 72 terceiros molares humanos extraídos, para expor superfície dentinária plana. Os dentes preparados foram divididos em: dentina sem pré-tratamento; dentina tratada com EDTA 0,1M; dentina tratada com EDTA 0,5M. Cada grupo recebeu tratamento de três sistemas adesivos autocondicionantes: Single Bond Universal (SBU), AdheSE (AdheSE) e Clearfil SE Bond (CSEB). Foi delimitada a área adesiva e assim posicionada uma matriz transparente, para inserção com resina composta Z250XT seguida de polimerização por 40 segundos. Após 24 horas de armazenamento, os dentes foram submetidos ao ensaio de microcisalhamento. Os dados obtidos foram analisados estatisticamente, utilizando-se os testes Two-Way ANOVA e Bonferroni, e sendo considerado nível de significância de 5%. Resultado Não houve diferença estatística significante na resistência de união entre os pré-tratamentos dentinários (p=0,8353), porém houve diferença significativa entre os adesivos (p<0,05) CSEB e AdheSE, mostrando semelhança entre CSEB e SBU, e entre SBU e AdheSE. Conclusão O pré-tratamento dentinário com solução de EDTA não afetou a resistência de união com nenhum dos sistemas adesivos autocondicionantes utilizados.


Abstract Introduction Self-etching adhesives have simplified adhesive technique and decreased the postoperative sensitivity. When applied on dentin, it acts on the smear layer, but it is still a challenge in the effectiveness of this removal. A substance used as a pre-treatment for the removal of the smear layer is disodium ethylenediaminetetraacetic acid (EDTA). Objective To evaluate the effects of EDTA in association with self-etching adhesive systems on micro-shear bond strength. Material and method The occlusal surfaces of 72 extracted human third molars were sectioned to expose a flat dentin surface. The prepared teeth were divided into: dentin without pre-treatment; dentin treated with 0.1M EDTA; dentin treated with 0.5M EDTA. Each group received treatment of 3 self-etching adhesive systems: Single Bond Universal (SBU), AdheSE (AdheSE), and Clearfil SE Bond (CSEB). The adhesive area was delimited and positioned a transparent matrix for insertion with Z250XT composite resin followed by polymerization for 40 seconds. After 24h of storage, the teeth were submitted to the micro-shear test. The data were analyzed statistically using the Two-Way ANOVA and Bonferroni tests, considering a level of significance of 5%. Result There was no statistically significant difference in bond strength between dentin pre-treatments (p = 0.8353), but showed a significant difference between CSEB and AdheSE adhesives (p <0.05), showing similarity between CSEB and SBU, and between SBU and AdheSE. Conclusion Dentin pretreatment with EDTA solution did not affect bond strength with any of the self-etching adhesive systems used.


Subject(s)
Adhesives , Treatment Outcome , Edetic Acid , Dentin , Sodium Hypochlorite , Efficacy , Shear Strength , Dentin Sensitivity , Polymerization
9.
Rev. odontol. UNESP (Online) ; 46(3): 131-137, May-June 2017. tab, ilus
Article in Portuguese | LILACS, BBO | ID: biblio-902652

ABSTRACT

Introdução: A evolução dos sistemas adesivos permitiu que os fabricantes desenvolvessem materiais com técnicas cada vez mais simplificadas, porém que, ainda assim, promovessem adequados valores de resistência de união imediata. Sugere-se que alguns tratamentos da superfície dentinária podem favorecer esse processo de adesão. Objetivo: Avaliar os efeitos de diferentes tratamentos, em superfície dentinária plana condicionada, sobre a resistência de união à microtração de sistemas adesivos do tipo "condiciona-e-lava" de dois passos. Material e método: Noventa e seis terceiros molares humanos foram divididos em 12 grupos (n=8), aleatoriamente, de acordo com o sistema adesivo utilizado (GI: Adper Single Bond 2 - 3M ESPE; GII: Prime & Bond 2.1 - Dentsply; GIII: Excite - Ivoclar Vivadent) e o tipo de tratamento do substrato dentinário condicionado (a: água; b: clorexidina + água; c: etanol; d: clorexidina + etanol). Todos os dentes foram restaurados com resina Charisma na cor A2 (Heraeus - Kulzer, Germany) e submetidos a ensaio mecânico de microtração (EMIC DL-2000). O teste estatístico realizado foi ANOVA a um fator, completado com teste de Tukey. Resultado: Os grupos GIIc, GIIIc e GIId apresentaram aumento significativo estatisticamente na resistência de união à microtração imediata. Conclusão: Os diferentes tratamentos da dentina condicionada não afetaram de maneira negativa a resistência de união para todos os sistemas adesivos testados e a utilização da técnica com etanol, associado ou não à clorexidina, parece ser uma interessante abordagem quando associada a sistemas adesivos "condiciona-e-lava" de dois passos.


Introduction: The development of adhesive systems allow manufacturers to develop materials with increasingly simplified techniques, but that still would promote adequate resistance values of immediate union. It is suggested that some treatments of dentin surface can facilitate the process of accession. Objective: To evaluate the effects of different treatments in conditioned flat dentin surface on bond strength to microtensile 2-step etch-and-rinse adhesive systems. Material and method: Ninety-six human third molars were divided into twelve groups (n = 8) randomly according to the used adhesive system (GI: Single Bond 2 - 3M ESPE; GII: Prime & Bond 2.1 - Dentsply; GIII: Excite - Ivoclar Vivadent) and type of treatment of the conditioned dentin (a: water; b: water + chlorhexidine; c: ethanol; d: chlorhexidine + ethanol). All teeth were restored with Charisma color A2 (Heraeus - Kulzer, Germany) and subjected to mechanical testing microtensile (EMIC DL-2000). The statistical test performed was ANOVA 1 factor supplemented with Tukey test. Result: GIIc groups GIIIc and GIId showed statistically significant increase in bond strength to immediate microtensile. Conclusion: The different treatments of dentin did not affect negatively the bond strength for all tested adhesive systems and the use of the technique with ethanol, with or without chlorhexidine, appears to be an interesting approach when combined with 2-step etch-and-rinse adhesive systems.


Subject(s)
Chlorhexidine , Dentin-Bonding Agents , Shear Strength , Dentin , Ethanol , Molar , Analysis of Variance
10.
RSBO (Impr.) ; 12(2): 143-150, Apr.-Jun. 2015. ilus, tab
Article in English | LILACS | ID: lil-792036

ABSTRACT

Introduction: Most of techniques for determining the occlusal vertical dimension (OVD) of edentulous patients are based on soft tissues references, which lead to measurement discrepancies. Objective: To propose a method to obtain the OVD of edentulous patients during the confection of complete dentures considering the lower facial height established by Ricketts (LFHr) or the lower facial height obtained from cephalometric analysis of dentulous patients (LFHd). Material and methods: The OVD of 11 edentulous patients was determined by the association of 3 clinical methods. On each patient's bite plates a metallic ball was fixed and the patient was submitted to lateral radiographic to obtain the lower facial height (LFHe) from cephalometric analysis. Additionally, from 40 lateral cephalograms of dentulous patients the LFHd was obtained. After that, the distance between metallic balls (DMB, in mm) was calculated to verify the linear difference when LFHe was changed to LFHd or LFHr, which provided the amount of wax to be added or removed from the bite plates, establishing a new method of OVD determination. LFHe, LFHd and LFHr values were submitted to t e z statistical tests and DMB differences were analyzed by Student's t-test (α=0.05). Results: LFHr (47.0±4.0o a) was statistically higher than LFHd (44.9±5.6o b) and LFHe (43.5±3.5o b). There was statistical difference on linear discrepancies calculated between the LFHe and LFHd (1.7±4.1mm a) or LFHr (4.2±4.1mm b). Conclusion: The use of the cephalometric analysis showed to be a useful auxiliary tool in determining the intermaxillary relationship. However, this method must be associated with different clinical methods of OVD determination and it is recommended that regional references are used to calculate the linear discrepancies.

11.
RSBO (Impr.) ; 11(2): 192-198, Apr.-Jun. 2014.
Article in English | LILACS | ID: lil-778280

ABSTRACT

Introduction: The alveolar bone resorption that occurs after tooth loss leads to maladaptation of prostheses over the mucosa, causing discomfort to the patient. However, these maladaptations can be solved by prosthesis relining. Objective: The aim of this study was to discuss based on the literature, the relining of complete and partial removable dentures. Literature review: Dentistry makes use of relining materials that can be either rigid or resilient, having a temporary or permanent characteristic. However, to obtain a satisfactory result, the knowledge of their indications, contraindications, advantages, disadvantages is required, in addition to the characteristics and types of materials. Patients should be aware of the importance of constant monitoring, or even the need to reline their dentures, as it is not possible to determine the biological tolerance of each individual. Conclusion: The installation and proservation phases become essential to minimize bone resorption, and also to achieve rehabilitative treatment success.

12.
RSBO (Impr.) ; 11(1): 28-40, Jan.-Mar. 2014. ilus, graf, tab
Article in English | LILACS | ID: lil-718003

ABSTRACT

ABSTRACT Introduction and Objective: This study aimed to evaluate the effect of Er:YAG (L) and diamond drills (DD) on: 1) the microshear bond strength (MPa); 2) the adhesive interface of two-step (TS) - Adper Scotchbond Multipurpose and one-step (OS) adhesives - Adper EasyOne, both from 3M ESPE. Material and methods: According to the preparation condition and adhesives, the samples were divided into four groups: DD_TS (control); DD_OS; L_TS and L_OS. 60 bovine incisors were randomly divided into experimental and groups: 40 for microshear bond strength (n = 10) and 20 for the adhesive interface morphology [6 to measure the thickness of the hybrid layer (HL) and length of tags (t) by CLSM (n = 3); 12 to the adhesive interface morphology by SEM (n = 3) and 2 to illustrate the effect of the instruments on dentine by SEM (n = 1)]. To conduct the microshear bond strength test, four cylinders (0.7 mm in diameter and 1 mm in height with area of adhesion of 0.38 mm) were constructed with resin composite (Filtek Z350 XT - 3M ESPE) on each dentin surface treated by either L or DD and after adhesives application. Microshear bond strength was performed in universal testing machine (EMIC 2000) with load cell of 500 kgf and a crosshead speed of 0.5 mm / min. Adhesive interface was characterized by thickness of hybrid layer (HL) and length of tags (t) in nm, with the aid of UTHSCSA ImageTool software. Results: Microshear bond strength values were: L_TS 34.10 ± 19.07, DD_TS 24.26 ± 9.35, L_OS 33.18 ± 12.46, DD_OS 21.24 ± 13.96. Two-way ANOVA resulted in statistically significant differences only for instruments (p = 0.047). Mann-Whitney identified the instruments which determined significant differences for HL thickness and tag length (t). Concerning to the adhesive types, these differences were only observed for (t). Conclusion: It can be concluded that 1) laser Er:YAG results in higher microshear bond strength values regardless of the adhesive system (TS and OS); 2) the tags did not significant affect the microshear bond strength; 3) the adhesive interface was affected by both the instruments for cavity preparation and the type of adhesive system used.

13.
Rev. odontol. UNESP (Online) ; 42(5): 330-335, set.-out. 2013. ilus, tab
Article in English | LILACS, BBO | ID: lil-690723

ABSTRACT

Objetivo: O estudo avaliou, em diversos períodos de análise, o pH e liberação de cálcio e a atividade antibacteriana proporcionada pelo MTA Fillapex, em relação ao Sealapex e AH Plus. Material e Método: Tubos de polietilenos foram preenchidos com um dos cimentos e imersos em água destilada. Após de 24 horas, 14 e 28 dias, o valor do pH e o cálcio liberado pelos cimentos foram avaliados diretamente na água destilada em que os espécimes permaneceram imersos. A atividade antibacteriana dos cimentos foi avaliada em culturas de Enterococcus faecalis ou Staphylococcus aureus, por meio do teste de difusão em ágar. Os dados obtidos foram submetidos aos testes de ANOVA e Tukey (α=0.05). Resultado: Em todos os períodos analizados, o Sealapex proporcionou os maiores valores de pH (p<0,05) em relação aos demais cimentos e o MTA Fillapex proporcionou maiores valores que o dos AH Plus (p<0,05). Em 14 dias, o MTA Fillapex promoveu maior liberação de cálcio que o proporcionado pelo Sealapex (p<0,05). Em 28 dias, o Sealapex proporcionou maior liberação de cálcio que o MTA Fillapex (p<0,05). Em todos os períodos, o AH Plus apresentou a menor liberação de cálcio em relação aos outros cimentos (p<0,05). Em relação ao E. faecalis, não foram observadas diferenças (p>0,05) entre as zonas de inibição de crescimento bacteriano produzidas pelos diveros cimentos. Em relação ao S. aureus, o Sealapex apresentou maior atividade antibacteriana que o MTA Fillapex e o AH Plus (p<0,05), que por sua vez foram semelhantes entre si (p>0,05). Conclusão: Após o período final de avaliação, o pH e a liberação de cálcio proporcionado pelo MTA Fillapex foram menores que os do Sealapex e maiores que os do AH Plus. A atividade antimicrobiana do MTA Fillapex não diferiu dos demais cimentos endodônticos.


Objective: This study evaluated, in several analysis periods, pH and calcium release and antibacterial activity provided by MTA Fillapex sealer compared to Sealapex and AH Plus sealers. Material and Method: Polyethylene tubes were filled with a sealer and immersed in distilled water. After 24 hours, 14 and 28 days, pH and calcium release by endodontic sealers were evaluated directly in water which the tubes were stored. Sealers antibacterial activity was evaluated against Enterococcus faecalis and Staphylococcus aureus by means of agar diffusion test. All data were submitted to ANOVA and Tukey tests (α=0.05). Result: In all periods evaluated, Sealapex had the highest pH value (p<0.05) in comparison to other sealers and MTA Fillapex provided higher pH values than AH Plus (p<0.05). In 14-days period, MTA Fillapex had greater calcium release value than Sealapex (p<0.05). In 28-days period, Sealapex provided higher calcium release than MTA Fillapex (p<0.05). In all periods, AH Plus provided lower calcium release than other sealers (p<0.05). In relation to E. faecalis, there were no differences among the sealers, in relation to antibacterial activity (p>0.05). In relation to S. aureus, Sealapex presented better antibacterial effectiveness than the MTA Fillapex and AH Plus (p<0.05), which were similar each other (p>0.05). Conclusion: In final evaluation period, pH values and calcium release provided by MTA Fillapex were lower than provided by Sealapex and higher than provided by AH Plus. The MTA Fillapex antimicrobial action was similar to other endodontic sealers.


Subject(s)
Staphylococcus aureus , Calcium , Analysis of Variance , Enterococcus faecalis , Dental Cements , Endodontics , Hydrogen-Ion Concentration
14.
RSBO (Impr.) ; 10(3): 211-216, Jul.-Sep. 2013. ilus, tab
Article in English | LILACS | ID: lil-695938

ABSTRACT

Introduction: Endodontic sealer residues on dentinal surface have negative effects on adhesion of adhesives system and/or can cause discoloration of the dental crown. Objective: To evaluate the efficacy of 95% ethanol in removal of residues of epoxy-based (AH Plus), methacrylate-based (Epiphany SE) or calcium-based (Sealapex) sealers on dentinal surface. Material and methods: Thirty-two bovine incisor dental crown fragments (0.5 mm x 0.5 mm) were treated with 17% EDTA and 2.5% NaOCl. The specimens were divided into three experimental groups (n = 10): G1 (AH Plus), G2 (Epiphany SE) and G3 (Sealapex). In each group was applied a coating of one endodontic sealer type and were left undisturbed for 5 minutes. After this period, the specimens were cleaned with 95% ethanol. The control group was composed by two specimens that did not receive any sealer or cleaning treatment. The sealer residues persistence after cleaning with 95% ethanol was evaluated by scanning electron microscopy (x500) and a score system was applied. Data obtained were analyzed by Kruskal-Wallis and Dunn tests (α = 5%). Results: Moderate amount of endodontic sealer residues were observed in all groups, regardless of the endodontic sealer compositions. G1, G2 and G3 presented similar amount of sealer residues on dentinal surface after cleaning with 95% ethanol (p > 0.05). Conclusion: 95% ethanol was inefficiency to remove completely AH Plus, Epiphany SE and Sealapex residues of sealer-contaminated dentin.

15.
Article in Portuguese | LILACS, BBO | ID: lil-661329

ABSTRACT

O conhecimento da etiologia de qualquer doença ou condição é primordial para um tratamento seguro e efetivo. Esta revisão da literatura tem por finalidade mostrar algumas opções para se tratar a hipersensibilidade dentinária (Hsdc). A perda de esmalte e do cemento na região cervical e consequente exposição dos túbulos dentinários levam a uma condição dolorosa e de desconforto para o paciente, denominada de Hsdc. Essa perda de estrutura dentária ocorre em virtude de formação de lesões cervicais por processos de recessão gengival, abrasão, erosão, abfração ou pela associação de dois ou mais fatores. Alguns tratamentos apresentados não são eficazes, porém há terapias efetivas, como: aplicação de oxalato de potássio, cloreto de estrôncio, vernizes fluorados, fluoreto de sódio, soluções de hidróxido de cálcio, cimento de ionômero de vidro, laser, dentifrícios dessensibilizantes, sistemas adesivos e procedimentos restauradores. Portanto, a identificação e a remoção dos fatores etiológicos são essenciais ao sucesso do tratamento da Hsdc quando associadas à obliteração dos túbulos dentinários, tendo-se como resultado a efetiva redução do movimento do fluido dentro dos mesmos e a diminuição da dor.


The knowledge of the etiology of any disease or condition is paramount to a safe and effective treatment. This literature review aims to show some options to treat dentine hypersensitivity (Hsdc). The loss of cervical enamel and cementum exposure of tubules leads to a painful condition and patient discomfort, called Hsdc. this loss of tooth structure occurs due to formation of cervical lesions in cases of gingival recession, abrasion, erosion, or abfraction by the association of two or more factors. Some treatments are not effective, but there are effective therapies, such as: application of ferric oxalate, potassium oxalate, potassium nitrate, fluoride varnish, solutions of calcium phosphate, adhesives and Bonding procedures. Therefore, the identification and removal of etiological factors is essential to successful treatment of Hsdc normally associated to tubules obliterate and consequent reduction of fluid motion within the dentin.


Subject(s)
Tooth Erosion , Dentin Sensitivity , Dentin Desensitizing Agents
16.
Rev. dental press estét ; 9(3): 48-57, Jul-Dec.2012. ilus, graf, tab
Article in Portuguese | LILACS, BBO | ID: biblio-857633

ABSTRACT

Introdução: o clareamento dentários pode ser avaliado por meio de técnicas comparativas subjetivas (visual) ou objetivas (instrumental). Essa última tem se mostrado mais adequado para tal tipo de avaliação. Métodos: a avaliação do sistema foi realizado em laboratório, utilizando-se uma câmara digital, escala de cores Vita Classical e tres diferentes tipos de iluminação. No total, foram realizadas 480 imagens. Em seguida, o software foi avaliado quanto à sua eficiência clínica. Para tal, foi selecionado um caso de microabrasão complementado com clareamento dentário fotoacelerado. Resultados: os testes laboratoriais com diferentes iluminantes apresentaram resultados similares. Clinicamente, foram obsaervados diferentes níveis de clareamento em cada uma das sessões clínicas realizadas. Discussão: os vários métodos objetivos disponíveis atualmente apresentam diferentes graus de imitação na análise da cor de corpos semitranslúcidos (por exemplo, dentes e materiais dentários). Essas estão relacionadas ao posicionamento e ao sistema de cor utilizado (por exemplo, RGB, CYM) por cada equipamento. Portanto, o método proposto apresenta algumas vantagens em relação aos sistemas objetivos, como a ausência da necessidade de manutenção do posicionamento da amostra ou do paciente, algoritmo calibrador e a geração de gráficos e laudos. Conclusões: as comprovações geradas pelo sistema proposto geram maior conforto e segurança durante o tratamento


Introduction: The dental bleaching outcome can be evaluated using subjective (visual) and objective (instrumental) comparative techniques. The latter has demonstrated more suitable results to that kind of evaluation. Methods: The assessment of the proposed system was realized in th laboratory using Vita Classical color pallets, digital camera and three different illuminations. In total, 480 images were acquired. Next, the software was evaluated to check its clinical efficiency.For this, a case of micro-abrasion complemented with photoacelerated dental bleaching was chosen. Results: The laboratorial tests with different illuminants showed similar results. Clinically different levels of dental bleaching were observed in each one of the clinical appointments realized. Discussion: The several objective methods available nowadays present different limitation levels when analysing semitranslucid samples (e.g. teeth and dental materials). These limitations are related with the samples's position and with the color space used by each system (e.g. RGB, CYM). Therefore, the proposed method shows some advantages when compared with the traditional objective methods, such as the absence of position maintenance of the sample or of the patient, calibration algorithm and generation of graphs and reports. Conclusions: The outcomes generated by the proposed system can provide more security both to patient and professional during the treatment


Subject(s)
Dental Materials , Esthetics, Dental , Image Processing, Computer-Assisted , Software , Tooth Bleaching
17.
RSBO (Impr.) ; 9(3): 266-271, Jul.-Sep. 2012. ilus, tab
Article in English | LILACS | ID: lil-748123

ABSTRACT

Introduction: Composite resins are materials that can present color changing when exposed to pigments. Objective: The aim of this study was to evaluate, in vitro, the color changing of composites after immersion in different substances for different periods. Material and methods: Two microhybrid composite resins: Charisma (Heraeus - Kulzer) and Opallis (FGM) were used. Red wine and acai pulp were also used as immersion medium. For this study, 32 specimens with 10 mm of diameter and 2 mm of thickness were used, divided into 4 groups: Group 1 - Opallis composite immersed in red wine solution; Group 2 - Opallis composite immersed in acai berry pulp solution; Group 3 - Charisma composite immersed in red wine solution; Group 4 - Charisma composite immersed in acai berry pulp solution. The specimens were evaluated in the following time periods: T0 - baseline, T1 - 24 hours, T2 - 48 hours, T3 - 72 hours and T4 - 96 hours. For the assessment of staining, a spectrophotometer for colorimetry was used (Color Guide 45 / 0, PCB 6807 BYK-Gardner Gerestsried GmBH, Germany), and the values obtained were transferred to a computer and recorded according to CIELAB system. Results: The data were evaluated using Kruskal- Wallis non-parametric tests with the following mean values for the immersion periods of 24, 48, 72 and 96 hours, respectively: G1 - 7.35, 7.84, 9.04,10.48; G2 - 2.92, 4.15, 4.30, 4.64; G3 - 3.14, 7.35, 8.13, 8.43, G4 - 4.49, 5.99, 6.92, 6.76. Conclusion: Red wine showed a higher tendency toward altering the composite color than acai berry pulp. In addition, no significant difference was found concerning to the behavior of the two composite resins. Concerning to the immersion time periods, significant differences were only observed among the groups in the 24 hour time period.

18.
RSBO (Impr.) ; 9(2): 133-136, Apr.-Jun. 2012. tab
Article in English | LILACS | ID: lil-748102

ABSTRACT

Introduction :Alkalinization potential is a fundamental property of endodontic epoxy-based cements containing calcium hydroxide. Studies have shown discrepant pH results for same materials at different evaluation periods. A possible reason accounting for these differences may be the assessment procedures. Objective: To evaluate the pH value of an epoxy-based cement (Sealer 26) in different periods of analysis, using two assessment methods. Material and methods:Sealer 26 was manipulated and immediately placed into polyethylene tubes (n=10, each group) and immersed in distilled water. In G1, the tubes were kept in the same water during all experiment; and in G2, the tubes were removed and placed into another flask with an equal amount of water after the pH evaluation. The pH of these solutions was measured at 24 hours, 7, 14 and 28 days. Analysis were made within the same group according to the experimental periods and between groups in each experimental period. Data were submitted to ANOVA (a = 5%) and t test, respectively.Results:For G1 and G2, all periods showed different pH values (p < 0.05), except between 14 and 28 days (p > 0.05) and between 7 and 14 days (p > 0.05), respectively. In each period, no significant differences were observed between the groups.Conclusion: The method to obtain the pH values in different experimental periods no interfered in the final results. However, difference was observed when the results were analyzed at same group.

19.
Braz. oral res ; 26(1): 19-23, Jan.-Feb. 2012. ilus, tab
Article in English | LILACS | ID: lil-622920

ABSTRACT

The aim of this study was to evaluate the efficacy of three rotary instrument systems (K3, ProTaper and Twisted File) in removing calcium hydroxide residues from root canal walls. Thirty-four human mandibular incisors were instrumented with the ProTaper System up to the F2 instrument, irrigated with 2.5% NaOCl followed by 17% EDTA, and filled with a calcium hydroxide intracanal dressing. After 7 days, the calcium hydroxide dressing was removed using the following rotary instruments: G1 - NiTi size 25, 0.06 taper, of the K3 System; G2 - NiTi F2, of the ProTaper System; or G3 - NiTi size 25, 0.06 taper, of the Twisted File System. The teeth were longitudinally grooved on the buccal and lingual root surfaces, split along their long axis, and their apical and cervical canal thirds were evaluated by SEM (×1000). The images were scored and the data were statistically analyzed using the Kruskall Wallis test. None of the instruments removed the calcium hydroxide dressing completely, either in the apical or cervical thirds, and no significant differences were observed among the rotary instruments tested (p > 0.05).


Subject(s)
Humans , Bone Cements/chemistry , Calcium Hydroxide/chemistry , Dental Pulp Cavity/chemistry , Root Canal Preparation/instrumentation , Dental Instruments , Microscopy, Electron, Scanning , Nickel , Statistics, Nonparametric , Surface Properties , Titanium
20.
RSBO (Impr.) ; 8(3): 271-276, Jul.-Sep. 2011. tab
Article in English | LILACS | ID: lil-720313

ABSTRACT

Introduction: MTA is composed of various metal oxides, calcium oxide and bismuth. It has good biological properties and is indicated in cases of endodontic complications. Several commercial formulations are available and further studies are necessary to evaluate these materials. Objective: To evaluate pH and calcium releasing of MTA Fillapex® compared with gray and white MTA. Material and methods: Gray and white MTA (Angelus) and MTA Fillapex® (Angelus) were manipulated and placed into polyethylene tubes and immersed in distilled water. The pH of these solutions was measured at 24 hours, 7 days and 14 days. Simultaneously, at these same aforementioned periods, these materials' calcium releasing was quantified, through atomic absorption spectrophotometry. The results were submitted to ANOVA, with level of significance at 5%. Results: Concerning to pH, the materials present similar behaviors among each other at 24 hours (p > 0.05). At 7 and 14 days, MTA Fillapex® provided significantly lower pH values than the other materials (p < 0.05). Regarding to calcium releasing, at 24 hours and 7 days, MTA Fillapex® provided lower releasing than the other materials (p < 0.05). After 14 days, differences were found between MTA Fillapex® and gray MTA (p < 0.05). Conclusion: All materials showed alkaline pH and calcium releasing, with significantly lower values for MTA Fillapex® sealer.

SELECTION OF CITATIONS
SEARCH DETAIL